Symptom
When users update ServeRAID M5200 Series SAS/SATA Controller firmware from 24.9.0-0026 to 24.21.0-0112 under OS or through BoMC, there is no error reported, but the firmware will not update successfully after system reboot. The firmware will still be displayed as version 24.9.0-0026 prior to the update.
(where BoMC = Bootable Media Creator)
Affected Configurations
The system is configured with one or more of the following Lenovo Options:
- ServeRAID M5210 SAS/SATA Controller for IBM System x, Option 46C9110, any any
- ServeRAID M5210e SAS/SATA Controller for IBM System x, Option 46C9117CTO, any any
- ServeRAID M5215 with 2GB Flash Enablement, Option 00JX142, any 00JX139/00MW400
- ServeRAID M5225-2GB SAS/SATA Controller, Option 00AE938, any model
This tip is not system specific.
This tip is not software specific.
The system has the symptom described above.
Workaround
24.9.0-0026 is a very early version. Users will need to update to a middle version such as 24.21.0-0052, and then update to the latest version 24.21.0-0112.
Additional Information
24.9.0-0026 was released in 2015, and 24.21.0-0112 was released in 2019. There are lots of fixes/enhancements between these two versions. The RAID controller will not allow users to update directly.
Source: https://support.lenovo.com/vn/en/solutions/ht509783